Profibus Factory

We produce Profibus connectors, profibus cables and etc.

This content shows Simple View


Category Archives SIEMENS S7-300

PC/MPI+:RS232 isolated Programming adapte for Siemens S7-300/400 PLC,6ES7972-0CA23-0XA0

Optoelectronic isolated RS232/MPI,Siemens S7-300/400 PLC Programming adapter cable,with communication indicator,can replace Siemens 6ES7 972-0CA23-0XA0,automatically adjust the communication speed from 19.2Kbps to 115.2Kbps for the PC port,automatically adjust the communication speed from 19.2Kbps to 187.5Kbps for the MPI interface.Can connect PLC and the touch panel of third party factory to communicate.It doesn't support profibus function.

PC/MPI+ adapter, or named PC adapter, could achieve the level conversion of RS232 to RS485 and the protocal conversion of RS232 to MPI(MultiPoint Interface).PC/MPI+ is the adapter of photoelectric isolation type towards industrial design. Between RS232 port and RS485 port exist the surge protection and anti-lightning protection circuit, adaptable to the full PLC series of Siemens S7-300/400 and those devices with MPI port, especially the industrial fields with greater interference and easily damaged communication port. All kinds of protection measures in the circuit give promission to the safe operation of the system.

PC/MPI+ can make touch-screen communications with the third party under the link of S7-300/400PLC, such as eView, Wei-lun and kun-lun state.

 

Characteristics and main technical parametres:

★ Power: It is supplied by the 24VDC MPI port of PLC, power consumption of about 1w, with overcurrent protection and surge protection.
★ Isolation Voltage: 1000VDC(Maximun to 3000 VDC, orders require statement.)
★ RS232 port has anti-surge protection, RS485 port has anti-lightning protection and overcurrent protection with the consumption of 500w.
★ RS232 port baud rate: 19.2Kbps—115.2Kbps, automatically adaptable to the standard baud rate.
★ MPI port baud rate: 187.5Kbps—19.2Kbps, automatically adaptable.
★ Supporting the connection of PLC to touch-screen communication with the third party.
★ With a power indicater light, on-line and data transmission indicater light.
★ Working temperature: -20~75'C
★ Dimension: 103×50×26; After connecting the RS232 cables: 5.5m.

RS232 adapter port and port-pin RS485 signal definations:

 

Pin number

Signal name

Instructions

 

Pin number

Signal name

Instructions

1

DCD

No use

1

NC

No use

2

RXD

RS232 signal reception

2

M24V

Negtive 24VDC power

3

TXD

RS232 signal sending

3

B

RS485 positive signal

4

DTR

Short circuit with No.6

4

RTSAS

Data reception control

5

GND

RS232 signal to ground

5

GND

RS485 signal to ground

6

DSR

Short cut with No.4

6

NC

No use

7

RTS

Sending requsts

7

P24V

24VDC positive power

8

CTS

Sending clear

8

A

RS485 negtive signal

9

RI

No use

9

RTS_PG

Data-send control

 RS232-Block(DB9M) defination signals RS485-Block(DB9M) defination signals

 

 

Indicater light

On

Qlittering

Out

Power

Normal

Error

Error or failing to link to power

Active

Online

Transmission of data

Not online

Tx

Error

Send data

No data transmission

 Instructions of the indicater light

Software settings of STEP7:
Entering the main interface of STEP7 programming software(SIMATIC Manager), clicking on “Options” menu under the “Set PG/PC Interface…” option into the PG/PC interface settings.
1. Double clicking on “PC Adapter(MPI)” into the RS232 interfaces and MPI set of parameters. The adapter does not support “PC Adapter(PROFIBUS)” option.
2. Clicking on “Local Connection” option set RS232 interface parameters, choosing PC/MPI to connect on the port of COM correctly, and it will adapt to the chosen baud rate automatically, both 19200bps and 38400bps of RS232 communication.
3. Clicking “MPI” to set port parameters of adapter MPI, acceptable at both 187.5Kbps and 19.2Kbps, and the adapter will adapt to its baud rate automatically. Others have already been set.
4. On-line test accessing point: Using PC/MPI to connect to MPI port and RS232 port of the computer. And then click on the button in the red circle as follow, if appearing the data inside the red line, the test has passed. Then one could operate on it.

The long-distance communication of PC/MPI+ adapter:

1. To extend the distance of RS485 port:

 2. To extend the distance of RS232 port:

RS232 Cable:

When you buy PC/MPI+,we will give you the free RS232 Cable.

The quality is guaranteed.It's tested before shippment.Not made by Siemens,OEM product as the replacement.

Link to PC/MPI:http://www.automation-world.com/plc-programming-cable/siemens-programming-cable/S7-300-S7-400-adapter

 




PC/MPI+:RS232 isolated Programming adapte for Siemens S7-300/400 PLC,6ES7972-0CA23-0XA0

The Difference Between MFI & MPI

Cars and acronyms may go together like peas and carrots, but the resulting alphabet soup could drive Buddha to fits. So you're excused for feeling a bit like a monkey at the prom, and wanting to ram a sock down your own throat in frustration when trying to tell the difference between terms like MPI and MFI. Especially these terms, which, like so many others, since they can often refer to the same kind of system using slightly different nomenclature.

TBI vs Multipoint Injection

  • The old throttle body injection system, or TBI, is something of an evolution of the carburetor, a stop-gap engineered to help manufacturers transition from carburetors to the electronic fuel-injection systems used today. The TBI unit bolts in place of the carburetor and sprays fuel under pressure into the engine. A multipoint system uses one injector for each one of the engine's cylinders. These individual injectors spray fuel directly onto the back of the intake valve, ensuring perfect fuel distribution to each cylinder.

MPI vs. MFI

  • In the common parlance, MPI and MFI are actually two different ways of referring to the same system. MPI breaks down as "multipoint injection," and MFI stands for "multipoint fuel injection." You could also abbreviate the latter as MPFI, MI or Fi. BMW originally dropped all but the last letter when referring to the same system and still uses the old "-i" suffix in spite of the fact that the company no longer manufactures a car without fuel injection.

MFI — Definition 2

  • The acronym MFI can also refer to mechanical fuel injection, a system in use since the earliest days of internal combustion. The primary difference between carburetion and fuel injection is that the former uses engine vacuum to suck fuel into the cylinders, while the latter sprays fuel into the engine under high pressure. A mechanical system is just that: it uses no electronic controls whatsoever, relying either on a fuel pump — as many diesels do — or a fuel distribution system to time fuel injection to crankshaft position.

EFI

  • Electronic fuel Injection differs from mechanical fuel injection in that it uses some sort of electronic controls to time the fuel injection cycle. The most basic type of EFI system consists of an oxygen sensor and a small control box that controls an auxiliary air valve. The fuel injection system is essentially mechanical, and the engine controls the air-to-fuel ratio by making minute adjustments the the amount of air going in. The modern EFI system uses a legion of sensors and electronic injectors to control how much fuel goes in and when.

     

PC/MPI+:RS232 isolated Programming adapte for Siemens S7-300/400 PLC,6ES7972-0CA23-0XA0

 

PC/MPI+9

BUYNOW-BUTTON2 $90.00

Optoelectronic isolated RS232/MPI,Siemens S7-300/400 PLC Programming adapter cable,with communication indicator,can replace Siemens 6ES7 972-0CA23-0XA0,automatically adjust the communication speed from 19.2Kbps to 115.2Kbps for the PC port,automatically adjust the communication speed from 19.2Kbps to 187.5Kbps for the MPI interface.Can connect PLC and the touch panel of third party factory to communicate.It doesn't support profibus function.

PC/MPI+ adapter, or named PC adapter, could achieve the level conversion of RS232 to RS485 and the protocal conversion of RS232 to MPI(MultiPoint Interface).PC/MPI+ is the adapter of photoelectric isolation type towards industrial design. Between RS232 port and RS485 port exist the surge protection and anti-lightning protection circuit, adaptable to the full PLC series of Siemens S7-300/400 and those devices with MPI port, especially the industrial fields with greater interference and easily damaged communication port. All kinds of protection measures in the circuit give promission to the safe operation of the system.

PC/MPI+ can make touch-screen communications with the third party under the link of S7-300/400PLC, such as eView, Wei-lun and kun-lun state.

Characteristics and main technical parametres:

★ Power: It is supplied by the 24VDC MPI port of PLC, power consumption of about 1w, with overcurrent protection and surge protection.
★ Isolation Voltage: 1000VDC(Maximun to 3000 VDC, orders require statement.)
★ RS232 port has anti-surge protection, RS485 port has anti-lightning protection and overcurrent protection with the consumption of 500w.
★ RS232 port baud rate: 19.2Kbps—115.2Kbps, automatically adaptable to the standard baud rate.
★ MPI port baud rate: 187.5Kbps—19.2Kbps, automatically adaptable.
★ Supporting the connection of PLC to touch-screen communication with the third party.
★ With a power indicater light, on-line and data transmission indicater light.
★ Working temperature: -20~75'C
★ Dimension: 103×50×26; After connecting the RS232 cables: 5.5m.

RS232 adapter port and port-pin RS485 signal definations:

 

Pin number

Signal name

Instructions

 

Pin number

Signal name

Instructions

1

DCD

No use

1

NC

No use

2

RXD

RS232 signal reception

2

M24V

Negtive 24VDC power

3

TXD

RS232 signal sending

3

B

RS485 positive signal

4

DTR

Short circuit with No.6

4

RTSAS

Data reception control

5

GND

RS232 signal to ground

5

GND

RS485 signal to ground

6

DSR

Short cut with No.4

6

NC

No use

7

RTS

Sending requsts

7

P24V

24VDC positive power

8

CTS

Sending clear

8

A

RS485 negtive signal

9

RI

No use

9

RTS_PG

Data-send control

 RS232-Block(DB9M) defination signals RS485-Block(DB9M) defination signals

 

 

Indicater light

On

Qlittering

Out

Power

Normal

Error

Error or failing to link to power

Active

Online

Transmission of data

Not online

Tx

Error

Send data

No data transmission

 Instructions of the indicater light

Software settings of STEP7:
Entering the main interface of STEP7 programming software(SIMATIC Manager), clicking on “Options” menu under the “Set PG/PC Interface…” option into the PG/PC interface settings.
1. Double clicking on “PC Adapter(MPI)” into the RS232 interfaces and MPI set of parameters. The adapter does not support “PC Adapter(PROFIBUS)” option.
2. Clicking on “Local Connection” option set RS232 interface parameters, choosing PC/MPI to connect on the port of COM correctly, and it will adapt to the chosen baud rate automatically, both 19200bps and 38400bps of RS232 communication.
3. Clicking “MPI” to set port parameters of adapter MPI, acceptable at both 187.5Kbps and 19.2Kbps, and the adapter will adapt to its baud rate automatically. Others have already been set.
4. On-line test accessing point: Using PC/MPI to connect to MPI port and RS232 port of the computer. And then click on the button in the red circle as follow, if appearing the data inside the red line, the test has passed. Then one could operate on it.

The long-distance communication of PC/MPI+ adapter:

1. To extend the distance of RS485 port

2. To extend the distance of RS232 port

RS232 Cable:When you buy PC/MPI+,we will give you the free RS232 Cable.

The quality is guaranteed.It's tested before shippment.Not made by Siemens,OEM product as the replacement.

Link to PC/MPI:http://www.automation-world.com/plc-programming-cable/siemens-programming-cable/S7-300-S7-400-adapter

More related pictures of PC/MPI+:

ABCD

A cable is most often two or more wires running side by side and bonded, twisted, or braided together to form a single assembly, but can also refer to a heavy strong rope. In mechanics, cables, otherwise known as wire ropes, are used for lifting, hauling, and towing or conveying force through tension. In electrical engineering cables are used to carry electric currents. An optical cable contains one or more optical fibers in a protective jacket that supports the fibers.

Electric cables discussed here are mainly meant for installation in buildings and industrial sites. For power transmission at distances greater than a few kilometres see high-voltage cable, power cables, and HVDC.

 

If you'd like to get more, you can click here to visit our company store directly.
 

 

Pls feel free to contact me if any question.

Tel:86-755-26898905-8002

Email:crystal@kollewin.com




Adapter,PC Adapter,PC Adapter CN

Adapter

An adapter or adaptor is a device that converts attributes of one device or system to those of an otherwise incompatible device or system.

Some adapters may only affect physical attributes:

  • An electrical adapter may enable connection of a socket used in one region to a plug used in another by offering connections for the disparate contact arrangements, while not changing the voltage. For more, see: AC power plugs and sockets.
  • A garden hose adapter can convert between threads and quick-release, "snap"-type connections.
  • One kind of serial port adapter enables connections between 25-contact and nine-contact connectors, but does not affect electrical power- and signalling-related attributes.

Other adapters may affect electrical attributes:

  • A transformer adapts household electric current from high voltage (100 to 240 volts AC) to low voltage suitable for consumer electronics. These adapters will warm through converting alternating current to direct current, but are safe to the environment and can withstand months of continuous prolonged activity. 

                  PC Adapter CN is one of them.

USB Adapter CN User Manual :   USB_Adapter_CN_User_Manual

PC Adapter CN USER MANUAL: PC-Adapter-CN-USER-MANUAL

PC Adapter CN:RS232 to PROFIBUS/MPI adapter

PC-Adapter-CN

BUYNOW-BUTTON2 $286.00

This adapter is compatible with Siemens PC Adapter and HMI adapter,fully support  RS232 port of PC and HMI to PROFIBUS/MPI communication, use the Siemens special protocol processing chip,it can be used for Siemens S7-300/400 series PLC and other equipments with PROFIBUS/MPI interface. RS232-RS485-power supply are all optical isolated, especially suitable for the strong interference and communication interface easily damaged industrial scene.
PC Adapter CN is a high-tech adapter compatible with Siemens PC Adapter and HMI Adapter,fully support RS232 serial port of PC and HMI to PROFIBUS/MPI communication, adopt the Siemens protocol processor chip,no functional defects. PC Adapter CN is the opto-isolated adapter for industrial design.It has the surge protection and anti-lightning protection circuit on the RS232 interface and RS485 interface, support hot plug, is suitable for Siemens S7-300/400 series PLC and other equipments with PROFIBUS/MPI interface. In particular, it applies to the strong interfere industrial situations and the safeguard in the circuit guarantees the safely running of the system.
PC Adapter CN can communicate between S7-300/400PLC and RS232 interface of third party HMI,can replace the Siemens HMI Adapter.

The low version PC/MPI+ didn’t adopt the Siemens protocol processor chip,but adopt the MCU and use the software to achieve the profibus protocol,the protocol is not perfect and has the defect,only support MPI communication,not support profibus communication,can only connect few HMI and have the defect. When there are many nodes or third-party device in the network,it can’t identify every node. At the same time, it may have the risk that PC/MPI+ can’t be used after the PLC internal program is upgraded in the future.
Main Technical Specifications:
                                                                         
● RS232 interface can connect PC or HMI etc third party devices,baud rate 9.6Kbps~115.2Kbps automatically adjust.
● Support PROFIBUS and MPI communication, auto bus protocol test,largest baud rate 1.5Mbps.
● Power supply from PLC port,24VDC, Power Consumption 2W,with over current and surge protection.
● Power-RS485-RS232 all isolated
● Opto-isolated voltage 1000VDC.
● RS232 interface has the anti-surging protection
● RS485 interface has the anti-lightning and surging protector, Repeatability surge capacity: Ipp=100A(10/700us,4KV),meet the standard ITU-TK20/21、VDE 0433. ±15KV ESD protection.
● Need additional 24VDC power for the long distance communication, the largest cable length meets the profibus standard.
● With the power indicator, data sending indicator, data receiving indicator
Can install the adapter on the S7-300/400PLC rail or 35MM standard rail.
● Shape Size: 123mm×68mm×30mm(Length*Width*Height),with the mounting bracket
● Working Temperature: -20~+75℃

 

If you'd like to get more, you can click here to visit our company store directly.

 

Pls feel free to contact me if any question.

Tel:86-755-26898905-8002

Email:crystal@kollewin.com

 




6ES7 321-1BL00-0AA0/ 6ES7 322-1BL00-0AA0,40 pin Connector,6ES7 392-1AM00-0AA0

 6ES7 321-1BL00-0AA0 and 6ES7 322-1BL00-0AA0 are the SM7-300 DIGITAL MODULE, and both of them need a 40 pin connector, that is 6ES7 392-1AM00-0AA0.

 6ES7 321-1BL00-0AA0

321-1BL00-0AA06ES7 972-0BB12-0XA0 button $191.00

Model

SM321

Number of digital inputs:32

Product  Description

32DI 24V DC,
High immunity

 

Power consumption

·From bus current consumption

50mA

·Power loss

6.5W

Number of digital inputs

32

Cable Length (Shielded)

1,000m

Cable Length (unshielded)

600m

Input voltage

·Rate value

24V DC

·For ”0” signal

-30~5V DC

·For ”1” signal

13~30V DC

·Frequency range

/

Input current

7mA

Input delay

 

·From “0”  to “1”,Min

1.2~4.8ms

·From “1”  to “0”,Min

1.2~4.8ms

Front connector

40-pin

Input type

NPN

Connection of 2-wire BERO sensor

Yes

Permissible quiescent current

1.5mA

Isolation tested for contact

·Between channel and backplane bus

Yes

·Per group between channels

Yes

The status indicates

Green LED each channel

Dimensions(WxHx D)(mm)

40×125×120

Order Number

 321-1BL00-0AA0

6ES7 322-1BL00-0AA0 

322-1BL00-0AA06ES7 972-0BB12-0XA0 button$264.00

Model

SM322

Number of digital outputs:32

Product  Description

32DO,24V DC; Transistor;

Optical isolation with high immunity

Power consumption

·From  bus current consumption

90mA

·Power loss

6W

Number of digital outputs

32

Cable Length (Shielded)

1,000m

Cable Length (unshielded)

600m

Short-circuit protection

Yes,Electronic

Inductive cutoff voltage

L+(-53V)

Lamp load Max

5W

Output voltage:”1” signal

Min,L+(-0.8V)

Output current:”1” signal

0.5A

Lifetime contact mechanical

/

Lifetime contact  mechanical  rated load voltage)

/

Sum of output currents(per group)

4A

IIsolation tested for contact

·To backplane bus

Yes,Optocoupler

·To per group between channels

Yes

Switching frequency for contacts

·Resistive loads,Max

100Hz

·Capacitive loads,Max

0.5Hz

·Lamp loads,Max

10Hz

·Mechanical load,Max

/

The status indicates

Green LED each channel

Front connector

40-pin

Dimensions(W x H x D)(mm)

40×125×120

Order Number

 322-1BL00-0AA0

40 pin Connector—6ES7 392-1AM00-0AA0

3926ES7 972-0BB12-0XA0 button $16.90

S7-300 front connector(40 pin)       S7-300,FRONT CONNECTOR WITH SCREW CONTACTS,40-pin                              

Production China
System Name: Simatic S7 System SubType: S7-300
Approx. Dimensions: 1" x 5" x 1" (3cm x 13cm x 3cm) Approx. Weight: 0 lbs, 4 oz (0.1 kg)

Not made by Siemens,but the quality is 100% guaranteed,1 year warranty.       

Inventory is accurate and up to date.
Please add items to your cart if you would like a formal quote or order online.

 

 

 

If you'd like to get more, you can click here to visit our company store directly.

 

Pls feel free to contact me if any question.

Tel:86-755-26898905

Email:crystal@kollewin.com

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 




6ES7331-7NF00-0AB0 SIMATIC S7-300, ANALOG 6ES73317NF000AB0

SIMATIC S7-300, ANALOG INPUT,SM 331, OPTICALLY ISOLATED,,8 AE; +/-5/10V, 1-5 V, +/-20MA,,0/4 TO 20MA, 16 BIT (55 MS),,1 COMMON POINT(50 V COM.),,1 X 40 PIN
SIMATIC S7-300, ANALOGEINGABE,SM 331, POTENTIALGETRENNT,,8 AE; +/-5/10V, 1-5 V, +/-20MA,,0/4 BIS 20MA, 16 BIT (55 MS),,EINZELWURZELUNG (50V COM.),,1 X 40-POLIG
SIMATIC S7-300, MOD.E ANALOG.,SM 331, CON AISL. GALVANICO,,8 EA; +/-5/10V, 1-5 V, +/-20MA,,0/4 A 20MA, 16 BITS (55 MS),,COMUN INDIVIDUAL (50V COM.),,1 X 40 POLOS
SIMATIC S7-300, MOD.E ANALOG.,SM 331, CON AISL. GALVANICO,,8 EA; +/-5/10V, 1-5 V, +/-20MA,,0/4 A 20MA, 16 BITS (55 MS),,COMUN INDIVIDUAL (50V COM.),,1 X 40 POLOS


Weight(Kg):0.316
Price(Euro):516.00




6ES7331-7PF11-0AB0 SIMATIC S7-300, ANALOG 6ES73317PF110AB0

SIMATIC S7-300, ANALOG INPUT,SM 331, OPTICALLY ISOLATATED,,8 AI THERMOCOUPLE,,TYPE B, E, J, K, L, N, R, S, T,TXK/TXK(L) ACCORDING GOST,16 BIT, 50 MS, 1 X 40 PIN
SIMATIC S7-300, ANALOGEINGABE,SM331, POTENTIALGETRENNT,,8 AE THERMOELEMENTE,TYP B, E, J, K, L, N, R, S, T,TXK/TXK(L) NACH GOST,16 BIT, 50 MS, 1 X 40-POLIG
SIMATIC S7-300, MOD.E ANALOG.,SM331, AISLAMIENTO GALV.,,8 EA TERMOPARES,TIPO B, E, J, K, L, N, R, NA, T,TXK/TXK(L) SEGUN GOST,16 BITS, 50 MS, 1 X 40 POLOS
SIMATIC S7-300, MOD.E ANALOG.,SM331, AISLAMIENTO GALV.,,8 EA TERMOPARES,TIPO B, E, J, K, L, N, R, NA, T,TXK/TXK(L) SEGUN GOST,16 BITS, 50 MS, 1 X 40 POLOS


Weight(Kg):0.334
Price(Euro):658.00




6ES7331-7TB00-0AB0 SIMATIC DP, HART ANALOG 6ES73317TB000AB0

SIMATIC DP, HART ANALOG INPUT,SM 331, 2 AI, 0/4 – 20MA HART,,FOR ET200M WITH IM153-2,,1 X 20 PIN
SIMATIC DP, HART ANALOGEINGABE,SM 331, 2AE, 0/4 – 20MA HART,,FUER ET200M MIT IM 153-2,,1 X 20-POLIG
SIMATIC DP, M. E ANALOG. HART,SM 331, 2AI, 0/4 – 20MA HART,PARA ET200M CON IM 153-2,,1 X 20-POLOS
SIMATIC DP, M. E ANALOG. HART,SM 331, 2AI, 0/4 – 20MA HART,PARA ET200M CON IM 153-2,,1 X 20-POLOS


Weight(Kg):0.349
Price(Euro):332.00




6ES7331-7KB82-0AB0 SIMATIC S7-300, ANALOG 6ES73317KB820AB0

SIMATIC S7-300, ANALOG INPUT,SM 331, OPTICALLY ISOLATED,,FOR EXPANDED TEMPERATURE RANGE,,2 AI, 9/12/14 BIT RESOLUTION,,U/I/THERMOCOUPLE/RESISTANCE,,INTERRUPT, DIAGNOSTICS, 20 PIN
SIMATIC S7-300, ANALOGEINGABE,SM 331, POTENTIALGETRENNT,,FUER ERWEIT. TEMPERATURBEREICH,,2 AE, AUFL.9/12/14 BIT,,U/I/THERMOEL./WIDERSTAND,,ALARM, DIAGNOSE, 20-POLIG
SIMATIC S7-300, MOD.E ANALOG.,SM 331, CON AISL. GALVANICO,,P/ RANGO TEMPERATURA EXTENDIDO,,2 EA, RESOL.9/12/14 BITS,,U/I/TERMOPAR./RESISTENCIA,,ALARMA, DIAGNOSTICO, 20 POLOS
SIMATIC S7-300, MOD.E ANALOG.,SM 331, CON AISL. GALVANICO,,P/ RANGO TEMPERATURA EXTENDIDO,,2 EA, RESOL.9/12/14 BITS,,U/I/TERMOPAR./RESISTENCIA,,ALARMA, DIAGNOSTICO, 20 POLOS

DISCONTINUED; ATTENTION! AVAILABLE AS A SPARE PART ONLY. SUCCESSOR: 6AG1331-7KB02-2AB0
TYPGESTRICHEN; ACHTUNG! NUR NOCH ALS ERSATZTEIL LIEFERBAR. NACHFOLGER: 6AG1331-7KB02-2AB0
Price(Euro):344.00




6ES7322-5GH00-0AB0 SIMATIC S7-300, DIGITAL 6ES73225GH000AB0

SIMATIC S7-300, DIGITAL OUTPUT,SM 322, OPTICALLY ISOLATED,,16 DA (SOLID STATE RELAY),,AC/DC 24 – 48V; 0.5A;,1.5A SURGE CURRENT, ONE CHANNEL,PER COMMON, 1 X 40 PIN
SIMATIC S7-300, DIGITALAUSGABE,SM 322, POTENTIALGETRENNT,,16 DA (SOLID STATE RELAIS),,AC/DC 24 – 48V; 0,5A MIT,EINERWURZELUNG, 1 X 40-POLIG
SIMATIC S7-300, MODULO S DIG.,SM 322, CON AISL. GALVANICO,,16 SD (SOLID STATE RELES),,24 – 48V AC/DC; 0,5A CON,COMUN INDIVIDUAL, 1 X 40 POLOS
SIMATIC S7-300, MODULO S DIG.,SM 322, CON AISL. GALVANICO,,16 SD (SOLID STATE RELES),,24 – 48V AC/DC; 0,5A CON,COMUN INDIVIDUAL, 1 X 40 POLOS


Weight(Kg):0.33
Price(Euro):459.00




6ES7332-5HB00-0AB0 SIMATIC S7-300, ANALOG 6ES73325HB000AB0

SIMATIC S7-300, ANALOG OUTPUT,SM 332, OPTICALLY ISOLATED,,2 AO, U/I; 11/12 BITS RESOL.,,20 PIN
SIMATIC S7-300, ANALOGAUSGABE,SM 332, POTENTIALGETRENNT,,2 AA, U/I; AUFLOES. 11/12 BIT,,20 PIN
SIMATIC S7-300, SALIDA ANALOG.,SM 332, CON AISL. GALVANICO,,2 SA, U/I; RESOL. 11/12 BIT,,20 PIN,ATENCION! SOLO DISPONIBLE COMO,PIEZA DE RECAMBIO!
SIMATIC S7-300, SALIDA ANALOG.,SM 332, CON AISL. GALVANICO,,2 SA, U/I; RESOL. 11/12 BIT,,20 PIN,ATENCION! SOLO DISPONIBLE COMO,PIEZA DE RECAMBIO!





360վȫƽ̨